Product Details:
| Minimum Order Quantity | 2000 Meter |
| Activation Temp | 78 °C |
| Cable Type | Digital LHD |
| Outer Sheath Material | Nylon |
| Max Zone Length | 2000 m |
| Application | Conveyor Belts, Warehouse, Cable Trays, Parking Garage, Tunnels |
| Approvals | UL |
| Color | Black |
By utilizing our years of experience, we bring forth a qualitative array of Digital Linear Heat Sensing Cable (LHS Cable). This heat detection cable is demanded in a wide variety of applications but is particularly suited where there is harsh environmental condition. Offered cable utilized for electrical control & switchgear cabinets, warehouse high rise pallet racking, oil rigs & off shore platforms. The primary mechanism of LHDC is that the inner core insulating polymer is specially formulated such that it plasticizes at a specific temperature.
Features:
Compatible with many existing zone monitors
Simple switch to operate a relay
UL Listed
Other Details:
Early Detection of hazards at temperatures well below flame point
Rugged construction—Stainless Steel outer sheath available (Optional)
Fixed Alarm Trigger Temperature
Compatible with many existing zone monitors / Control Equipment
Intrinsically Safe Configurable for Hazardous Areas (Devices to be purchased separately)
UL Listed
Extensive single zonal lengths of the LHDC Digital may be installed with the ability to trigger alarms for hot spots occurring on very small sections of the overall cable
The Linear Heat Detection Cable may be employed in a wide variety of applications but is particularly suited where there is harsh environmental condition, a physical or hazardous maintenance access constraint to protect the area, and / or a requirement to cost effectively install detection in close proximity to the risk(s)
The primary mechanism of LHDC is that the inner core insulating polymer is specially formulated such that it plasticizes at a specific temperature
Cable Construction:
The Digital Linear Heat Detection Cable comprises of a twisted pair twin core cable
Each core is of tinned copper coated spring steel and has a special heat reactive polymer insulation
The cable has an overall protective jacket / sheath
LHDC Digital may be used as a simple switch to operate a relay etc
However in most installations the minimum requirement is that the LHDC circuit is monitored for disconnections by means of EOL device and an appropriate fire alarm channel or address loop interface unit
Applications:
Cable Tunnels, Ducts & Mezzanines
Escalators & Moving Walkways
Petrochemical Storage Tanks / Rim Seal Protection
Paint Shops & Spray Booths
Conveyors - Coal, Wood Sulphur etc
Ceiling Voids & Attic Spaces
Road & Rail Tunnel Carriageways
Nuclear Reactor Plant Areas
Refrigerated Stores & Cold Rooms
Electrical Control & Switchgear Cabinets
Warehouse High Rise Pallet Racking
Oil Rigs & Off Shore Platforms
Fume Cupboards & Glove Boxes
Grain Silos & Agricultural Storage
Road / Rail Vehicle Engine Compartments
Steam pipe Leeks & Trace Heating Faults
Product Lines - Flanges, Valves & Pumps
Computer Room under Floor Cable Voids
Additional Information:
Product Details:
| Minimum Order Quantity | 1000 Meter |
| Activation Temp | 54°-100° |
| Cable Type | Analog LHD |
| Outer Sheath Material | PVC |
| Max Zone Length | 500 m |
| Application | Conveyor Belts, Warehouse, Cable Trays, Tunnels, Parking Garage |
| Approvals | SIL 2 Apporved |
| Conductor Size | 1.5 sq mm |
Linear heat sensing cables are widely used in areas where traditional detectors may fail:
Product Details:
| Minimum Order Quantity | 2000 Meter |
| Activation Temp | 68 °C |
| Cable Type | Digital LHD |
| Outer Sheath Material | Nylon |
| Max Zone Length | 2000 |
| Application | Cable Trays, Tunnels, Warehouse, Conveyor Belts, Parking Garage |
| Approvals | UL |
| Country of Origin | Made in India |
A Linear Heat Sensing Cable is a highly reliable and effective fire detection solution for large scale commercial and industrial premises.
The thermistor elements are sensitive to temperature changes, and in the event of a fire, the heat causes the resistance of the thermistor to change. This change in resistance triggers the fire alarm system and alerts the occupants of the building.
The Linear Heat Sensing Cable is an ideal solution for large areas that are difficult to protect with conventional smoke detectors.
It is also suitable for use in hazardous environments, where traditional fire detection methods may not be appropriate.
This cable is flexible, durable and can be easily installed and integrated into most fire alarm systems.
Applications:
Cable Tunnels, Ducts & Mezzanines
Escalators & Moving Walkways
Petrochemical Storage Tanks / Rim Seal Protection
Paint Shops & Spray Booths
Conveyors - Coal, Wood Sulphur etc
Ceiling Voids & Attic Spaces
Road & Rail Tunnel Carriageways
Nuclear Reactor Plant Areas
Refrigerated Stores & Cold Rooms
Electrical Control & Switchgear Cabinets
Warehouse High Rise Pallet Racking
Oil Rigs & Off Shore Platforms
Fume Cupboards & Glove Boxes Grain Silos & Agricultural Storage
Road / Rail Vehicle Engine Compartments
Steam pipe Leeks & Trace Heating Faults
Product Lines - Flanges, Valves & Pumps
Computer Room under Floor Cable Voids
Additional Information:
Product Details:
| Activation Temp | 78 °C |
| Cable Type | Digital LHD |
| Outer Sheath Material | Nylon |
| Max Zone Length | 1000 m |
| Application | Parking Garage, Conveyor Belts, Cable Trays, Warehouse, Tunnels |
| Approvals | UL |
| Conductor Size | 1.5 sq mm |
| Color | Black |
| UV Resistance | Yes |
Linear heat sensing cables are widely used in areas where traditional detectors may fail: